If your refrigerator is not cooling properly or has excessive frost buildup, a faulty defrost timer could be the culprit. The defrost timer controls the defrost cycle, preventing ice accumulation on t...
READ MORE120*120*38mm COOLING FAN is a high-performance fan with dimensions of 120mm×120mm×38mm. It is designed to provide powerful heat dissipation for electronic devices and is suitable for various industrial and computer application scenarios. The fan adopts advanced bearing technology, operates stably and with low noise, and can run for a long time without generating too much heat. Its large air volume can effectively reduce the temperature of the equipment and extend the life of the equipment.
Model | Size | Rating Voltage(VAC) | Power Current(AMP) | Power Consumption(WATTS) | Speed(RPM) | Air Flow(CFM) | Noise(SBA) | Bearing | Weight(g) |
WK12038D1HSL | 120X120X38 | 12 | 0.30 | 4.0 | 2500 | 85.0 | 42 | Sleeve | 250 |
WK12038D2HSL | 120X120X38 | 24 | 0.20 | 4.8 | 2500 | 85.0 | 42 | Sleeve | 250 |
Model | Frequency Hz |
Voltage V |
Bearing Type | Current Amp |
Power W |
Speed Rpm |
Airflow Cfm |
Noise dB(A) |
Weight Gram |
FM12038A1HSL | 50/60 | 110 | Sleeve | 0.24/0.23 | 26/23 | 2800 | 90/100 | 40/45 | 500g |
FM12038A1HBL | 50/60 | 110 | Ball | 0.24/0.23 | 26/23 | 2800 | 90/100 | 40/45 | |
FM12038A2HSL | 50/60 | 220 | Sleeve | 0.14/0.13 | 26/23 | 2700 | 90/100 | 40/45 | |
FM12038A2HBL | 50/60 | 220 | Ball | 0.14/0.13 | 26/23 | 2700 | 90/100 | 40/45 | |
FM12038A3HSL | 50/60 | 380 | Sleeve | 0.07/0.06 | 26/23 | 2700 | 90/100 | 40/45 | |
FM1 2038A3HBL | 50/60 | 380 | Ball | 0.07/0.06 | 26/23 | 2700 | 90/100 | 40/45 | |
FM12038A1/A2HSL | 50/60 | 110/220 | Sleeve | 0.23/0.14 | 26/23 | 2700 | 90/100 | 40/45 | |
FM12038A1/A2HBL | 50/60 | 110/220 | Ball | 0.23/0.14 | 26/23 | 2700 | 90/100 | 40/45 | |
FM=Factory Model,12038 =120*120*38mm,A1=AC 110V, A2=AC 220V,H=High speed, S=Sleeve,B=Ball,L=Lead wire,T=Terminal |
If your refrigerator is not cooling properly or has excessive frost buildup, a faulty defrost timer could be the culprit. The defrost timer controls the defrost cycle, preventing ice accumulation on t...
READ MOREIf your HVAC system is struggling to start, making humming noises, or not cooling properly, a faulty capacitor could be the issue. Replacing it is a common repair, but costs can vary. CBB65-R3 Averag...
READ MOREThe air conditioner magnetic contactor is a key component for controlling the on-off of the circuit in the air conditioning system, and its performance directly affects the stability and service life ...
READ MORE